Brian,
Did you profile the build? maybe the scanner locking up.
Also check that the setpoints for the temps going out of the warm-up to the build stage are the same, otherwise it waits for the temps to stabilize at the setpoint. If the differance between the warm up s/p and the build stage s/p is greater than the deadband (10 degrees) it willlock up every time.

good luck
jac
---------- Original Message ----------------------------------
From: Brian Caulfield <brian.caulfield@nuigalway.ie>
Date: Wed, 18 Sep 2002 12:40:49 +0100

>Hi all,
> I had a problem today with a build on a SLS 2500+ and I was wondering if you have any solutions. The build started of fine on the warm up stage but when it switches to the build stage the system just seems to stall. The build profile seems to be fine. Any ideas?
>