re: SLS problem

From: Guido Zanini (gzanini@eosimage.it)
Date: Wed Sep 18 2002 - 16:39:43 EEST


Hi Brian
you can try this :
a- if Sinterstation software is working, try to push PAUSE BUILD and after
RESUME BUILD, if the sinterstation don't switch to the build stage, try to
PAUSE BUILD, TERMINATE BUILD and in a very short time push START BUILD (the
system will ask THERE IS AN UNFINISHED BUILD, RESTART ? Yes)
b-if Sinterstation software is not responding there is only a choice: you
must kill all the active process and reset all the system above all the
scanner control MS-DOS PC.-
Bye

Guido Zanini
EOS Image s.r.l.
Via kennedy, 44-25028 VEROLANUOVA (BS)
tel. 0309361414 fax 0309361426
e-mail gzanini@eosimage.it - www.eosimage.it

For more information about the rp-ml, see http://rapid.lpt.fi/rp-ml/