Re: appropriate laser power?

From: Nelson Low (nellow@hotmail.com)
Date: Tue Oct 10 2000 - 09:21:24 EEST


Hello,

The part-bed temperature should be about 10-12 degreeC below the melting pt
of Duraform. The melting pt is abt 186, if I remembered correctly. You can
use the default setting for Duraform, and use a laser power of abt 6-10W.
Hope it helps.

Regards,
Nelson Low
Nanyang Technological University
Singapore

> ----- Original Message -----
> From: H.Byun
> To: rp-ml@bart.lpt.fi
> Sent: Monday, October 09, 2000 10:22 AM
> Subject: appropriate laser power?
>
>
> Hi
> Recently, I had the upgrate for SLS 2000. So, I want to use DuraForm P/A
>instead of Nylon . But I dont know the appropriate process parameters.
>Anyone know ? when DuraForm is used, what watt is laser power? what is
>temperature ? in warmup stage, build stage and coolin stage.
> Please, let me know it.
> thank you in advance.

_________________________________________________________________________
Get Your Private, Free E-mail from MSN Hotmail at http://www.hotmail.com.

Share information about yourself, create your own public profile at
http://profiles.msn.com.

For more information about the rp-ml, see http://ltk.hut.fi/rp-ml/