At 16:27 Uhr -0500 09.02.2000, KDenton@williams-int.com wrote:
>Hello All,
>
>I have some parts that have really tiny bubbles in them. They are QuickCast
>parts on a machine running a doctor blade. Any suggestions on getting rid
>of them? This is a first for me!
>
>Karl Denton
>
Karl,
You can try to collect the bubbles on one side: If you sweep slower
than 10 seconds the bubbles will follow the sweeper blade. If you
sweep faster than 5 seconds the bubbles will remain more or less in
the same place. I think effect is best if you sweep at 200%
Best regards,
Markus Hitter
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Dipl. Ing. Markus Hitter http://www.fh-trier.de/~hitterm
RET - Markus Hitter Technologie der Produktentwicklung
Fortschritt in der Entwicklung Konstruktion
Stereolithografie
fon: +49 - (0)651 8103-530
fax: +49 - (0)651 8103-258