RE: Accuracy Study of 15 RP Systems

From: J $B5# (joe@nttd-cmet.co.jp)
Date: Tue Mar 09 1999 - 03:28:04 EET


I have a table which summarized the results from Dr.K. Loose's Paper.

System
Working Size

LxWxH(mm) Accuracy Small Details
                Average Error
(mm) Square
$B!J(JL x L$B!'(Jmm$B!K(J Hole(J
$B!J(JDia.$B!'(Jmm$B!K(J (J
                        
0.6
0.4
0.2
0.6
0.4
0.2
SOUP$B-6(J600GS 600x600x500 0.04 $B!{(J $B!{(J $B!_(J $B!{(J $B!{(J $B!_(J (J
SCS-1000HD 300x300x270 0.04 $B!{(J $B!{(J $B!_(J $B!{(J $B!_(J $B!_(J (J
Soliform500B 500x500x500 0.07 $B!{(J $B!_(J $B!_(J $B!{(J $B!_(J $B!_(J (J
SLA 5000 500x500x500 0.15 $B!v(J $B!v(J $B!v(J $B!v(J $B!v(J $B!v(J (J
UR$B-6(J-SP1501 EP 150x150x150 0.18 $B!_(J $B!_(J $B!_(J $B!_(J $B!_(J $B!_(J (J
UR$B-6(J-SP1501 AC 150x150x150 0.22 $B!{(J $B!_(J $B!_(J $B!{(J $B!_(J $B!_(J (J
SLP-5000 220x200x225 0.29 $B!_(J $B!_(J $B!_(J $B!_(J $B!_(J $B!_(J (J
ModelMaker$B-6(J 304x152x228 0.07 $B!{(J $B!{(J $B!_(J $B!{(J $B!_(J $B!_(J (J
Actua 2100 250x200x200 0.22 $B!{(J $B!{(J $B!_(J $B!{(J $B!{(J $B!_(J (J
Genisys 203x203x203 0.13 $B!_(J $B!_(J $B!_(J $B!_(J $B!_(J $B!_(J (J
MM-6PRO 152x152x152 0.14 $B!_(J $B!_(J $B!_(J $B!_(J $B!_(J $B!_(J (J
FDM2000 254x254x254 0.23 $B!_(J $B!_(J $B!_(J $B!_(J $B!_(J $B!_(J (J
Sinterstation 2500 380x330x420 0.17 $B!_(J $B!_(J $B!_(J $B!_(J $B!_(J $B!_(J (J
Z402 3D Printer 203x254x203 0.28 $B!_(J $B!_(J $B!_(J $B!_(J $B!_(J $B!_(J (J
LOM-1015E 370x240x360 0.10 $B!{(J $B!{(J $B!{(J $B!{(J $B!_(J $B!{(J (J
KSC-50N 380x260x300 0.16 $B!_(J $B!_(J $B!_(J $B!_(J $B!{(J $B!_(J (J
Remark: $B!{(J can create the small detail(J
           $B!_(J can not create the small detail(J
$B!v(J the measured size was about 0.13 - 0.25 mm bigger than CAD.(J

PhD Yi XU $B=y(J $B5#(J

NTT DATA CMET
Kamata Tsukimura Bldg 7F, 5-15-8, Ohta-ku, Tokyo 144-0052, Japan
Tel: +81-3-3739-6611
Fax:+81-3-3739-6680
www.nttd-cmet.co.jp

-----Original Message-----
From: MR ALBIN A HASTBACKA [SMTP:KHVD07A@prodigy.com]
Sent: Tuesday, March 09, 1999 9:41 AM
To: rp-ml@bart.lpt.fi
Subject: Accuracy Study of 15 RP Systems

-- [ From: Al Hastbacka * EMC.Ver #2.5.3 ] --

In a 1998 study by K. Loose of the Institute of Physical and Chemical
Research (RIKEN) and Dr. T. Nakagawa of the Institute of Industrial
Science at the University of Tokyo, the absolute accuracy of fifteen
different rapid prototyping systems was measured. The absolute accuracy
of the tested systems, when fabricating a 50 x 50 x 30 mm part, is
summarized below:

    RP System Error
                                         
                                                            mm HGA's
Ink Jet RP Systems
                                        
Sanders ModelMaker II 0.07 2.76
Sanders MM-6PRO 0.14 5.51
ACTUA 2100 0.22 11.18
                                        
SLS & 3D Printing
                                        
DTM Sinterstation 2500 0.17 6.69
Z Corp Z402 0.28 11.02
                                        
Laminated Object Manufacturing
                                        
Helisys LOM-1015E 0.1 3.94
KIRA KSC-50N 0.16 6.30
                                        
Fused Deposion Modelers (FDM)
                                        
Stratasys Genisys 0.13 5.12
Stratasys FDM 2000 0.23 9.06
                                        
Stereolithography Systems
                                        
DMEC SCS-1000D 0.04 1.57
CMET SOUP II 600 0.04 1.57
Teijin Seiki Soliform 500B 0.07 2.76
3D Systems SLA 5000 0.15 5.91
Unirapid URII-SP1501(SOMOS 6100) 0.18 7.09
Unirapid URII-SP1501(SOMOS 3100) 0.22 8.66
Denken SLP-5000 0.29 11.42

If you would like to see more details of the test results,
please reply with a direct Email to me.

Regards,
Al Hastbacka